PC vs ABS vs Fiberglass Waterproof Enclosures: Which Material Should You Choose?

Strength and price are usually the first two things buyers ask about. They’re rarely what decides it. Leave a PC box, an ABS box and a fiberglass box on the same outdoor site for a couple of years and you’ll see three different stories: how each one took the sun, the damp, whatever chemicals were around, the hot days and cold nights, the knocks. That’s the part worth paying attention to.
We mostly deal with electrical engineers, OEMs and panel builders, plus distributors and industrial buyers. Different jobs, same request really. Protect the gear inside, and don’t make me pay for performance I won’t use. So here’s how the three materials compare, and what we’d check before signing off an order (IP rating, where it’s going, testing, custom work).
Understanding PC, ABS, and Fiberglass Enclosures
Polycarbonate (PC) Enclosures
PC is a thermoplastic, and it earns its place mostly on impact resistance. It also keeps its shape well. And it’s the one you reach for when the customer wants to see inside, because transparent covers are easy to get. Outdoor electrical controls use it a lot. So do monitoring equipment, comms systems and electronic housings in general.
Outdoors? UV-stabilized grades usually cope fine. Usually. It comes down to the exact formulation, and two boxes both sold as “UV PC” won’t necessarily age the same. Watch the chemicals too. Certain solvents and cleaning agents cause stress cracking in PC, so it pays to ask what the maintenance team actually sprays on things.
ABS Enclosures
ABS (acrylonitrile butadiene styrene) is the default for junction boxes. You’ll also find it on control equipment and on a huge share of general-purpose electronic enclosures.
Why so common? Cheap to make. Molds without fuss. Comes out of the tool with a nice finish. Inside a building, or anywhere it’s sheltered, it’s hard to argue with. Sunlight is its weak spot, though, because standard grades break down if they sit in UV long enough. Going outside with ABS means using a grade formulated for it, and having the test data in hand rather than taking someone’s word.
Fiberglass Enclosures
Fiberglass enclosures are glass-fiber-reinforced plastic. FRP or GRP on the datasheet, same thing. Utilities like them. So do wastewater plants, heavy industrial sites and pretty much anywhere the conditions are rough.
The glass in the matrix is what gives you the stiffness, the mechanical strength and a good chunk of the chemical resistance. How much you get, though, is down to the resin system, the reinforcement and how well the part was made. In our industry the name that comes up most is SMC (sheet molding compound), a fiberglass-based material used widely for electrical enclosures.
People sometimes treat fiberglass as bulletproof against every chemical and any weather. It isn’t. Grade matters here just as much as anywhere else.
PC vs ABS vs Fiberglass: Key Differences
Table 1. Material Comparison for Waterproof Electrical Enclosures
Factor | Polycarbonate (PC) | ABS | Fiberglass (FRP/GRP) |
Impact resistance | Typically high | Good for general use | Depends on composite design |
UV resistance | Good with suitable UV grade | Standard grades are less suitable outdoors | Depends on resin and finish |
Chemical resistance | Chemical-specific | Chemical-specific | Often good with suitable resin |
Structural rigidity | Good | Suitable for lighter-duty uses | Often high |
Temperature performance | Grade-dependent | Grade-dependent | Resin-dependent |
Electrical insulation | Good | Good | Generally good |
Transparent covers | Commonly available | Less common | Usually separate window |
Cost | Moderate to higher | Often economical | Depends on construction; often higher |
Typical applications | Outdoor controls, telecom | Indoor controls, junction boxes | Industrial and corrosive environments |
Treat that table as a rule of thumb. It’s general behavior, not a spec anyone will guarantee, and a particular grade or box design may well perform differently. The datasheet for the actual product is what counts.
What Makes an Enclosure Waterproof?
Here’s something that catches people out: the plastic isn’t what keeps the water out. The whole assembly does.
Lid, gasket, screws, cable glands, any other hole in the box. If one of them doesn’t seal, nothing else matters. We’ve seen properly rated enclosures leak simply because an installer fitted the wrong gland, or drilled an extra entry on site and never sealed it right.
IP codes come from IEC 60529, which sets out how enclosure protection is classified. For waterproof boxes, these are the ones that keep turning up on specs:
Table 2. IP Ratings Commonly Specified for Waterproof Enclosures (IEC 60529)
IP Rating | Protection |
IP65 | Dust-tight; protection against water jets |
IP66 | Dust-tight; protection against powerful water jets |
IP67 | Dust-tight; protection against temporary immersion |
IP68 | Dust-tight; protection against immersion under specified conditions |
IP68 needs a conversation with the manufacturer. How deep was it immersed, and for how long? The code leaves that to be agreed, so the number alone tells you little. And IP68 does not mean it also passed the IP66 water-jet test. Different test entirely. Need both? Then write both into the spec.
On a B2B job it really boils down to one question. With every accessory fitted, does the finished box still hit the protection level you need?
Choosing the Right Material for Your Application
Indoor and Sheltered Installations
Indoor junction boxes, control circuits, electronic housings: ABS, nine times out of ten. It’s practical and it keeps the cost down.
PC comes in when the job asks for more impact resistance, or a clear cover, or has operating requirements that push you that way.
Outdoor Installations
Outdoors is a different life. Sun, rain, the temperature going up and down, maybe the occasional hit from a ladder or a vehicle. On outdoor sensors, comms gear and electrical controls, UV-stabilized PC is normally near the top of the shortlist.
For bigger or tougher industrial installs, fiberglass is a strong candidate, particularly when rigidity and environmental resistance are high on the list. Don’t skip the UV check on it, mind you.
Coastal and Chemical Environments
Near the coast it’s another matter. Same with chemical plants, wastewater sites and some agricultural installs. Chemical compatibility needs proper attention there.
Fiberglass composites can do well in certain corrosive settings. The catch is that the resin has to suit the specific substances on site. And PC and ABS? They have chemical limits of their own.
Before you order, get the facts. Which chemical, at what concentration? At what operating temperature, and for how long will the box be exposed? There’s no such thing as a material that resists everything.
Temperature, Impact, and Internal Layout
Picking the material is half of it. The other half is making sure the box actually suits the equipment going in.
Two sources of heat to think about. Sun on the outside, electrical losses on the inside, and both raise the temperature in the box. So ask for the operating-temperature range in °C. A vague line about the material won’t do.
Could it get hit? Then look at impact resistance. IK ratings for impact protection are defined in IEC 62262. For flammability of polymeric materials there’s UL 94, which classifies them under specified test conditions. Something that gets misread a lot: UL 94 is a material rating. A box made from a UL 94 material isn’t automatically a certified enclosure.
And give the inside some breathing room. Mounting plate, DIN rails, cable runs, terminals, space to get a hand in for maintenance later. Plenty of boxes look fine on paper and turn out to be a pain to wire.
What B2B Buyers Should Check Before Ordering
Material plus IP rating plus outside dimensions doesn’t make a purchase spec. Not a reliable one anyway. This is what we go through with buyers:
Table 3. Waterproof Enclosure Procurement Checklist
Specification | What to Verify |
Application | Indoor, outdoor, industrial or corrosive environment |
Material | Exact PC, ABS or fiberglass grade |
Dimensions | Height × width × depth in mm |
IP rating | Required protection and supporting test evidence |
Temperature | Operating range in °C |
UV resistance | Outdoor suitability and weathering data |
Chemical resistance | Compatibility with actual exposure |
Impact/fire performance | Required IK or material classification |
Internal layout | Mounting plate, DIN rails, bosses or inserts |
Cable entries | Gland sizes, positions and openings |
Gasket and hardware | Sealing material, fasteners and hinges |
Documentation | Drawings, datasheets and applicable test reports |
Quantity | Sample, project batch or bulk order |
Custom order? Get a drawing approved first. Every time. That’s how you avoid surprises with dimensions or mounting points, cable entries that end up in the wrong place, or equipment that doesn’t quite fit.
Testing and Quality Verification
Testing only counts if it was done on the actual enclosure model — the one heading into the real application.
On waterproofing, ask for the evidence behind the IP rating. Then check how the sample was set up. Glands, windows, extra openings… they all change the result.
On the production side, inspectors need to be looking at dimensions and lid alignment, gasket fit, fasteners and mounting features, plus the overall moulding or fabrication quality.
Outdoor projects usually need more: UV-weathering data, temperature tests, impact tests, and sometimes a chemical-resistance evaluation.
If you’re buying empty enclosures for low-voltage switchgear and controlgear assemblies, IEC 62208:2023 is the standard to check — it sets out the requirements and testing guidance within its scope.
Bottom line: verify the product you’re actually paying for. A test report borrowed from some other enclosure series proves almost nothing.
FAQ
Is PC better than ABS for outdoor enclosures?
If it’s going to sit outside for years, UV-stabilized PC usually wins, especially when sun and impact are the worries. For indoor or sheltered spots ABS still does the job perfectly well.
Is fiberglass stronger than polycarbonate?
Depends what kind of strong. Fiberglass composites can be very rigid and structurally strong. PC is the tough one when it comes to impact. Grade, design and the type of load decide which comes out on top.
Can all three materials achieve IP66 or IP67?
Yes, all three can, if the enclosure is designed properly. It’s the complete construction and proven sealing that get you there. Material alone won’t.
Is fiberglass completely corrosion-proof?
No. It won’t rust like carbon steel does, sure. But some chemicals and environmental conditions will still attack the resin.
Which material is most economical for bulk orders?
ABS, a lot of the time, as long as the application suits it. Where exposure is harsh or maintenance is a headache, though, PC or fiberglass can pay for itself over the life of the install.
Order Custom Waterproof Enclosures from SKKBO
We make plastic waterproof enclosures at SKKBO. They go into industrial controls and electrical distribution, automation, communication equipment and outdoor installs.
Depending on what the project needs, we’ll build in ABS, polycarbonate (PC) or SMC fiberglass-reinforced material. Customization is wide. Dimensions, mounting arrangements, clear covers and cable-entry openings, gaskets, brackets, locks, plus OEM branding if you want your own name on it.
Want a quote? Send over the enclosure dimensions and tell us where it’s going, what material you’d prefer and what IP rating you need. Add the equipment layout and cable-entry details, any drawings you’ve got, and roughly how many you’ll order.